Conductivity Testers & Meters
Conductivity Testers
Taetron’s water conductivity testers are devices that are used to measure the electrical conductivity of water. Conductivity is a measure of how well a solution can conduct electricity, and in water, this property is determined by the concentration of dissolved ions, such as salts and minerals. The meter may be a simple handheld device or a more advanced instrument with features such as automatic temperature compensation, data logging, and multiple ranges of measurement. High levels of conductivity in water can indicate the presence of dissolved salts and minerals which may be harmful to aquatic life or may affect the taste and quality of drinking water.
Taetron’s water conductivity testers are composed of electrodes, circuitry, display, power source, calibration solutions, meter, and carrying case.
The other common names of conductivity testers are conductivity meters, electrical conductivity analyzers, conductance meters, salinity testers, total dissolved solids meters, electrolyte conductivity testers, ion concentration analyzers, cell constant meters, dissolved ion concentration meters, electrical conductance probes, solution conductivity sensors, ionic strength meters, electrolyte concentration analyzers, conductivity measurement instruments and specific conductance meters.
Benchtop High Precision PH Conductivity Meter
This Benchtop High Precision pH Conductivity Meter has a pH range of-1.99 pH to 19.99 pH, resolution of 0.1/0.01/0.001 pH, and accuracy of ±0.002 pH.
Technical Specifications
PH Range | (-1.999 pH to 19.999 pH) |
PH Resolution | 0.1 pH or 0.01 pH or 0.001 pH |
PH Accuracy | Meter: ±0.002 pH |
MV Measuring range(mV/ORP/EH) | -1999.9 mV to 0 mV to 1999.9 mV |
MV Resolution | 0.1 mV |
MV Accuracy | ±0.03% FS |
Benchtop PH/Conductivity Meter
Technical Specifications
Range | -2.000 pH to 20.000 pH |
Accuracy | ±0.002 pH |
Resolution | 0.1 pH, 0.01 pH, 0.001 pH, selectable |
Calibration Points | 1 to 5 points |
PH Buffer Options | USA, NIST, DIN or Custom |
Taetron Benchtop Conductivity Meter
Taetron benchtop conductivity meter is an exquisite and compact design concept, saves space for you, and brings you a new experience.
Technical Specifications
Conductivity Accuracy | ± 0.5 % FS |
TDS Measurement Range | 0.0000 ppm to 200.0 ppt |
TDS Resolution | 0.001mg or L to 0.1g or L |
TDS Accuracy | ± 0.5 % FS |
Salinity Measurement Range | 0.0 g or L to 260.0 g or L |
Salinity Resolution | 0.1 g or L |
Salinity Accuracy | ± 0.5 % FS |
Electric Thermal Portable Conductivity Meter
This Electric Thermal Portable Conductivity Meter has a range of 0.000 μS/cm to 1000 mS/cm, accuracy of ±1.0% FS, and salinity accuracy of ±0.2%.
Technical Specifications
Resolution | 0.001 μS/cm minimum, various with range selection |
Accuracy | ±1.0% FS |
Reference Temperature | 68 °F to 77 °F (20 °C to 25 °C) |
Calibration Points | Up to 3 |
Standard Recognition | 84 μS/cm, 1413 μS/cm, 12.88 mS/cm |
Taetron Digital Electrical Conductivity
Technical Specifications
Resolution | 1 uS per cm |
Accuracy | ± 1 uS per cm |
Temperature Compensation | Automatic |
Shell Material | Stainless Steel |
Measuring Range | 1 μS per cm to 20000 μS per cm |
Thread | G 3 per 4 |
Taetron Accurate Digital Conductivity
Taetron accurate digital conductivity are reliable and accurate test instruments for measurement of conductivity of aqueous solutions.
Technical Specifications
Function | Amount of soluble ions present in the soil. electrical conductivity |
Grade | As per ip or usp standards |
Application | Used to evaluate the quality of water – is the water drinkable |
Feature | Microcontroller based |
Material | Made with best raw materials. |
Taetron Acidity Conductivity Dissolved Oxygen Meter
This Acidity Conductivity Dissolved Oxygen Meter has ±0.01 pH/ 3 h pH stability, ≤2 × 10-12 A pH input current, and ≤85% environmental humidity.
Technical Specifications
pH Measurement Range | -2.00 pH to 19.99 pH |
Resolution | 0.1 pH or 0.01 pH |
Accuracy | Electric meter: ± 0.01 pH, matching: ± 0.02 pH |
Input Current | ≤2 × 10-12 A |
Input Impedance | ≥1 × 1012 Ω |
Stability | ±0.01 pH / 3 h |
Taetron Advanced Portable Lab Conductivity Meter
Technical Specifications
pH Range | -2 pH to 20 pH |
pH Accuracy | ±0.002 pH |
Resolution | 0.1, 0.01, 0.001 pH, Selectable |
Calibration Points | 1 point to 5 points |
Calibration Solutions | USA (pH 1.68 or 4.01 or 7.00 or 10.01 or 12.45), NIST (pH 1.68 or 4.01 or 6.86 or 9.18 or 12.45), DIN (pH 1.09 or 4.65 or 6.79 or 9.23 or 12.75) or User-defined |
mV Range | -1999.9 mV to 1999.9 mV |
Taetron Affordable Fuel Oil Conductivity Tester
Taetron Affordable Fuel Oil Conductivity Tester is based on the analysis of insulation permeability and electromagnetic induction charge characteristics for octane number of gasoline and cetane number of diesels.
Technical Specifications
Measurement Range | 0.5/1 |
Name | Detector |
Measurement Item | Types of gasoline |
Octane Number Measurement Range | 40 to 120 (Accuracy 0.5) |
Cetane Number Measurement Range | 20 to 100 (Accuracy 1) |
Data Display | Digital display |
Taetron All-in-one Portable Digital pH Meter Pen and Pocket Tester – High accuracy at 0.1 pH
The All-in-one Portable Digital pH Meter Pen and Pocket Tester offers high accuracy at 0.1 pH, providing reliable and convenient water quality testing in a compact design.
Technical Specifications
Resolution | 1 mV 0.1 mV, 1 mV, Selectable
0.1 mV, 1 mV, Selectable |
Calibration Points | 1 point (Only for Relative mV mode) |
Ion Concentration Range | 0.001 ppm to 19999 ppm, mg per L, mol per L (Refer to the range of ISE) |
Ion Concentration Accuracy | ± 0.5 % F.S (Monovalent), ± 1 % F.S (Divalent) |
Calibration Points | 2 points to 5 points (0.001 ppm, 0.01 ppm, 0.1 ppm, 1, 10 ppm, 100 ppm, 1000 ppm, 10000 ppm, mg per L, mol per L) |
Taetron Automatic Conductivity Meter
Technical Specifications
Display | 7 inch capacitive touch screen |
PH Measurement Range | -2 pH to 19.99 pH |
PH Resolution | 0.1 pH or 0.01 pH |
PH Accuracy | ± 0.02 pH |
PH Stability | ± 0.01 pH or 3 h |
MV Range | -1999.9 mV to 1999.9 mV |
MV Resolution | 1mV |
Taetron Automatic Conductivity Tester
Taetron Automatic Conductivity Tester can test PH, Conductivity (Salinity), DO, Temperature.
Technical Specifications
pH Buffer Recognition | US (pH4.01, 7.00, 10.01) or NIST (pH4.00, 6.86, 9.18), user selectable. | |
Buffer Temp range | 32.0°F to 140.0°F (0.0 ℃ to 60.0 ℃) | |
pH Calibration | 1-, 2- or 3-point calibration. | |
pH Electrode Offset Recognition | ±1.50 pH | |
pH Electrode Slope Recognition | ±30% at pH4.00, pH 4.01, pH 9.18 or pH 10.01. | |
pH Temp Compensation | Auto / manual 32.0°F to 212.0°F (0.0 ℃ to 100.0 ℃) |
Taetron Comprehensive Battery Conductivity Tester
Taetron Comprehensive Battery Conductivity Tester adopts a color resistance touch screen, and the instrument operation is flexible and convenient through finger or stylus touch; It is a digital storage multifunctional portable tester that can quickly and accurately measure the operating status parameters of batteries.
Technical Specifications
Measuring range (Conductivity) | 20 to 19990 S |
Measuring range (Internal resistance) | 0.01 m Ω to 120 m Ω |
Measuring range (Voltage) | 0.000 to 16 V |
Minimum measurement resolution (Conductivity) | 1 S |
Minimum measurement resolution (Internal resistance) | 0.01 m Ω |
Minimum measurement resolution (Voltage) | 1 mV |
Taetron Conductivity TDS Salinity Meter
This Conductivity TDS Salinity Meter has an mV range of -1999.9 mV to 1999.9 mV, pH resolution of -1.99 pH to 19.99 pH, and ≥1×1012 Ω input current.
Technical Specifications
pH Measurement Range | -1.99 pH to 19.99 pH |
pH Resolution | 0.1 pH or 0.01 pH |
pH Accuracy | ±0.02 pH |
Input Impendence | ≤1 × 10 -12 A |
Input Current | ≥1 × 1012 Ω |
pH Stability | ±0.01 pH / 3 h |
mV Range | -1999.9 mV to 1999.9 mV |
Taetron Automatic Temperature Compensation
This Automatic Temperature Compensation has a 7 inch capacity touch screen of display, 150 sets of data storage, and IP 54 of IP rating.
Technical Specifications
Display | 7 inch capacitive touch screen |
PH Measurement Range | -2 pH to 19.99 pH |
PH Resolution | 0.1 pH or 0.01 pH |
PH Accuracy | ± 0.02 pH |
PH Stability | ± 0.01 pH or 3 h |
Temperature Range | 32 °F to 212 °F (0℃ to 100℃) |
Temperature Compensation | 32 °F to 212 °F (0℃ to 100℃) |
MV Range | -1999.9 mV to 1999.9 mV |
Taetron Automatic Temperature Compensation Conductivity
This Temperature Conductivity Meter has 7-in LCD, electrode constant 0.1 cm-1 or 1 cm-1 or 10 cm-1, and salinity of 0 ppt to 100 ppt.
Technical Specifications
Display | 7-Inch LCD |
Electrode Constant | 0.1 cm-1 or 1 cm-1 or 10 cm-1 |
Communication | USB |
Calibration | 1 Point |
Resolution | 0.01 μS/cm 0.1 μS/cm 1 μS/cm 0.01 mS/cm 0.1 mS/cm 1 mS/cm |
Accuracy | Electrode: ±1.0% FS, Instrument: ±1.50%FS |
Conductivity Range | (0.00 to 20.00) μS/cm (20.0 to 200.0) μS/cm (200 to 2000) μS/cm (2.00 to 20.00) mS/cm (20.0 to 200.0) mS/cm |
Taetron Automatic Temperature Water Conductivity Meter
Technical Specifications
Measurement Range | (0 μs/cm to 199.9 μs/cm) (200 μs/cm to 1999 μs/cm) (2.00 ms/cm to 19.99 ms/cm) (20.0 ms/cm to 199.9 ms/cm) |
Resolution | 0.1 μs/cm or 1 μs/cm ;0.01 ms/cm or 0.1 ms/cm |
Accuracy | Electrometer: ±1.0% FS; Matching: ±1.5% FS |
Temperature Compensation Range | 50 °F to 122 °F (10 ℃ to 50 ℃) |
Temperature Coefficient | 35.6 °F (2.0% or 2.0 ℃) |
Electrode | DJS-1E (platinum black) electrode 018 Temperature Electrode |
Calibration | 1408 μs/cm |
Power Supply | AAA DC 1.5 V battery of 4 pcs |
Taetron Battery Cell Conductance Tester
Taetron Battery Cell Conductance Tester is a key component of the power system, batteries must be tested and maintained annually, quarterly or even monthly and their test data needs to be analyzed on a regular basis.
Technical Specifications
Measurement range | Conductance: 20 to 19,990 S Internal resistance: 0.000 mΩ to 99.999 mΩ Voltage: 0.000 V to 25 V |
Minimum measurement resolution | Conductance: 1 S Internal resistance: 0.001 mΩ
Voltage: 1 mV |
Measurement Accuracy | Conductance: ±0.5% ±6 dgt Internal resistance: ±0.5% ±6 dgt Voltage: ±0.2% ±6 dgt |
Power Supply | 11.1 V, 2400 mAh, rechargeable Lithium battery, can work 8 hours continuously |
Display | 5 in color LCD touch screen |
Memory | 64MB Flash + 4G SD card |
Temperature range | 32 °F to +140 °F (0 ℃ to +60 ℃) |
Taetron’s water conductivity testers have the following functions:
- Determining water purity– Taetron water conductivity testers can be used to measure the purity of water by detecting the presence of dissolved salts and minerals that can affect the taste and quality of the water.
- Monitoring water quality– In environmental monitoring applications, they are used to monitor water quality and detect any changes that may indicate pollution or other environmental factors.
- Controlling water treatment processes– Our water conductivity testers are used in water treatment plants to control the concentration of dissolved salts and minerals in the water, which can affect the efficiency of treatment processes.
- Ensuring the safety of aquatic life- High levels of conductivity in water can be harmful to aquatic life, and our water conductivity testers are used to monitor water quality in aquariums and other aquatic environments to ensure the safety of the animals.
- Conducting research- Taetron’s water conductivity testers are also used in research applications to study the properties of water and its interaction with other substances.
- Detecting contaminants– Taetron water conductivity testers can also be used to detect the presence of contaminants in water. Some contaminants, such as heavy metals and organic compounds, can affect the electrical conductivity of water.
Taetron’s water conductivity testers are rugged, versatile, and precision measurement instruments. They comply with applicable industry standards such as ASTM D1125, ISO 7888, EPA Method 120.1, and EN 27888.
Our water conductivity testers help our customers comply with U.S. government regulations such as:
- Safe Drinking Water Act (SDWA)
- Clean Water Act (CWA)
- Environmental Protection Agency
Our water conductivity testers help our clients in complying with relevant Canadian government regulations such as:
- Canadian Environmental Protection Act (CEPA)
- Fisheries Act
- Provincial and territorial regulations
Taetron’s water conductivity testers have the following applications:
- Water treatment– Taetron water conductivity testers are used in water treatment plants to monitor the quality of water and ensure that it meets regulatory standards. This includes testing the conductivity of raw water, as well as monitoring the effectiveness of water treatment processes such as reverse osmosis (RO) and deionization.
- Aquaculture– In aquaculture operations, water conductivity testers are used to monitor the quality of water in fish tanks, ponds, and other aquatic environments. This includes testing the water’s conductivity, as well as monitoring other water quality parameters such as pH, dissolved oxygen, and temperature.
- Swimming pools and spas– Our water conductivity testers are used to monitor the quality of water in swimming pools and spas. This includes testing the conductivity of the water to ensure that it is safe for swimmers and monitoring other water quality parameters such as pH and chlorine levels.
- Environmental monitoring– Our water conductivity testers are used in environmental monitoring applications to test the quality of water in rivers, lakes, and other bodies of water.
- Laboratory research– Taetron water conductivity testers can be used in laboratory research to measure the conductivity of water and other aqueous solutions.
Our water conductivity testers can be shipped overnight within the continental U.S. and Canada, and can be shipped globally.